Hello, welcome to visit the website of Dongguan Qiyue Wire and Cable Testing Equipment Co., Ltd.
Contact us
13712887191
Dongguan Qiyue Wire and Cable Testing Equipment Co., Ltd.
Your location:Home > Products > Concave detection machine >

Surface Concave detection machine

Release time:2019-10-22 10:35Popularity:

1 . Surface     concave- convex detector operation principle
a 、 The  following explanation chart is   1  axis. The  number of  receipt  devices is  2,  and this structure can guarantee    the accuracy of  the measurement  result.
 
 
receipt devices
 
Figure 1
 
When the  cable passes in  the  inspection machine, the  quantities of  light of  the  receiver are fixed values. The change occurs, and if it appears on  the  surface of  the  cable there is a concave- convex, the    quantities of     light of the receiver can do the defective concave- convex it detection.
 
 
emitting diode
 
 
cable
 
A     Figure 2
 
 
glas  lens
 
glas  lens
 
 
 
2 . Specification
 
 
The signal of  the pulse appears when the defect   appears
 
Direction of  detection:         3 direction
Model:                       FK-0503 CR、 FK-2003 CR、 FK -3003 CR、 FK -5003 CR
Range of measurement diameter: ① : Φ 0 . 0 2 m m ~ Φ 1 0 mm( FK- 0503 CR)
② : Φ 0 . 0 2 mm~ Φ 2 0 m m ( FK- 2003 CR)
③ : Φ 0 . 0 5 m m ~ Φ 3 0 m m ( FK- 3003 CR)
④ : Φ 0 . 1 m m ~ Φ 5 0 m m ( FK- 5003 CR)
Detection slit:                 Double     slit    type
Source of  light:              Near- infrared radiation light emitting diode( LED) Range of  detection sensitivity:           0 . 0 2 m m ~ 0 . 9 9 m m        ① ②
0 . 0 5 m m ~ 9 . 9 9 m m ③ ④ ( range of set level) Detection accuracy:                      Within  ± 1%  of  the maximum set value
Line swinging tolerance:         Horizontal direction  ± 0 . 0 1 m m
Vertical       direction  ± 0 . 0 1 m m
Line     speed:                    5 m / m i n ~ 1 5 0 0 m / m i n
Response:                      1 5 H z ~ 3 0 K H z
Alarm output:                 Concave    or     convex     output,    Red    lap lighting and relay
 
point of  contact output, Output   time about 0. 1 sec .
A C 2 5 0 V       2 A Resistance      load
Operating temperature:         - 5 ℃ ~ 5 0 ℃ ( However, there must not be dewy. )
Power:                       ± 1 5 V ( Within± 5 % )
Interface:                 RS-485 interface s

Recommendation information

13712887191